Abstract:In order to realize real-time monitoring of phospholipid content in soybean oil degumming process, a real-time detection system for phosphatidylcholine (PC) content in artificial soybean crude oil was developed based on photoelectric chemical biosensor. The result showed that SnO2 nanoparticles (SnO2 NPs)/Polythionine (PTh)/Choline oxidase (ChOx) (SnO2 NPs/PTh/ChOx) was successfully combined on indium tin oxide (ITO) electrode, and the composite electrode could produce good photocurrent signal for PC content in artificial soybean crude oil. The maximum photocurrent intensity was 4.60μA. In addition, the photocurrent signals of 100 artificial soybean crude oil samples with different PC content were collected by electrochemical workstation, and the data of 100 samples were processed by wavelet transform denoising and partial least squares regression model (PLSR). The coefficient of determination R2 of the test set model was 0.89, the root mean square error of prediction (RMSEP) was 24.98mg/L, and the relative standard deviation (RSD) was 0.13%, indicating that the model was stable and reliable. A real-time detection system for PC content in artificial soybean crude oil was developed by using LabVIEW and its performance was tested. The results showed that the RSD of the system was less than 4.00%, which was similar to the detection result of the electrochemical workstation, and the detection step was effectively simplified. In conclusion, the research result provided some theoretical support for real-time monitoring of residual phosphorus in soybean oil during oil degumming in industrial field. These findings can help optimize the extraction and refining process of soybean oil and improve production efficiency, which had important implications for its application in the food and industrial sectors.