Abstract:Aiming at the issue of manual operation required for feeding and stacking trays in existing automatic transplanters, which results in a low level of automation, a method for continuous feeding and stacking trays in transplanters was proposed. A device for continuous feeding and stacking trays in transplanters was designed based on multi-sensor fusion technology, and the structure and working principle of the device were analyzed. The design and optimization of the horizontal tray feeding mechanism, longitudinal stepwise tray moving mechanism, vertical continuous tray picking and placing mechanism, dual opening and closing tray stacking mechanism, and control system were carried out. Kinematic models for each stage of the tray movement were established. The Box-Behnken central combination test was used to study the role of tray tilt angle, tray feed air pressure, hole bottom distance on the continuous rate of seedling tray articulation, and the design of orthogonal tests through analysis of variance and response surface analysis showed that when the tray feed air pressure was 0.37MPa, the tray drop tilt angle was 27.29°, and the hole bottom distance was 5.26mm, the optimal rate of seedling tray articulation was 96.81%, to transfer disk deviation as an indicator to carry out the transfer disk toggle position accuracy test concluded that the maximum deviation of the step transfer disk was 14.17%. Under the condition of meeting the highest planting efficiency of the transplanter, the optimal parameter combination was used to conduct field tests, and the results showed that when the planting efficiency reached 128 plants/min, the continuous rate of seedling tray articulation was 95%, and the success rate of stacking trays was 99%. All the performances met the working requirements of the transplanter. The proposed method of continuous tray supply and collection can significantly improve the automation degree of the transplanter, and the research result can provide technical support for the research and development of tray supply and collection of the transplanter.